Ceiling suspended Daikin - Inverter 5.5HP - FHA140CVMA/RZF140CVM + BRC7M56 (1pha, remote không dây)

Ceiling suspended Daikin - Inverter 5.5HP - FHA140CVMA/RZF140CVM + BRC7M56 (1pha, remote không dây)

Ceiling suspended Daikin - Inverter 5.5HP - FHA140CVMA/RZF140CVM + BRC7M56 (1pha, remote không dây)

staff staff HUY CHUONG 2 hybrid balance filter air deoxidation paint smart eye
4-way suspended Promotion clean AC free
Product details
  • Ceiling suspended Daikin - Inverter 5.5HP - FHA140CVMA/RZF140CVM + BRC7M56 (1pha, remote không dây)
  • Price :49.650.000 VNĐ
  • Made in : THAILAND
  • Size : DL: 295 x 798 x 370 - DN: 595 x 795 x 300
  • Manufacturer : DAIKIN
  • Capacity : 5.5HP
  • Use : Use for room 61-80m3
  • Warranty: : 1 years - 5 years for compressor
  • Views : 202
  • Urusara 7 brings you to a new level of comfort by offering a unique, total comfort experience for any lifestyle. Latest advances in Japanese air conditioning technology is now at your fingertips.

    • Energy saving
    • Next-generation refrigerant
    • Humidity control
    • Airflow control
    • Designed in Japan
    • Air purification
    • Automatic filter cleaning
  • Order Download
  • FUNCTIONS
  • DATA ENGINEERING

ITEMS

FUNCTIONS

DESCRIPTIONS

1

DC - Inverter

An inverter is a device for converting frequency. The technology is used in many home appliances and controls the electric voltage, current and frequency. Inverter air conditioners can vary their cooling/heating capacity by adjusting the power supply frequency of their compressors. In contrast, non-inverter air conditioners have a fixed cooling/heating capacity and can only control the indoor temperature by starting or stopping their compressors. As a result, inverter air conditioners are more energy-saving and comfortable than non-inverter air conditioners.

2

Intelligent Eye

Intelligent Eye with its infrared sensor automatically controls air conditioner operation according to human movement in a room. When there is no movement, it adjusts the temperature by  +/-  2 C for energy savings.

3

Circulation Airflow

This function uses the Coanda effect to rapidly achieve the set temperature. The double air intakes and cross flow fan increase airflow to circulate air around a room.

4

Vertical Auto-Swing (up and down)

This function automatically moves the flaps up and down to distribute air across a room. The flap can direct warm air straight down to the floor during heating operation.

 

5

Auto Off Operation

Auto Off Operation uses 3-Area Intelligent Eye to

automatically stop operation if no movement is detected in a room. A detection period of one or three hours can be set.

6

Standby Electricity Saving

Even when an air conditioner is not operating, it requires standby power. However, thanks to this function, the required standby power can be reduced This function is available for FTKV50/60/71 and FTKC50/60.

7

Econo Mode

This mode limits maximum running current and power

consumption. This improves operating efficiency and also

prevents circuit breakers from being overloaded.

8

Inverter Powerful Operation

This function is convenient for boosting cooling/heating

performance for a 20 minute period both when the air

conditioner is first turned on or it is necessary to change the room temperature quickly.

9

Information Display

The LCD provides various details on current operation,

including temperature and humidity. It also displays

information such as total energy use over several days.

10

Wireless Remote Controller with Backlight

The large LCD and backlit buttons allow easy operation in the dark. Frequently used functions are conveniently located on the front of the controller.

11

Indoor Unit Lamp Brightness Setting

he indoor unit is equipped with an operation lamp, timer

lamp and various other indicators. The brightness of these lamps can be adjusted to High, Low or Off.

12

Indoor Unit On/Off Switch

The unit can be conveniently started manually in the

event the wireless remote controller is misplaced or the

wireless remote controller batteries are not charged.

13

Sarara Dry  Operation

The computer chip works to rid the room of humidity while maintaining the most consistent temperature possible. It automatically controls the temperature and airflow rate.

14

Automatic Operation

This function automatically selects cooling or heating

operation mode based on the room temperature at start-up.

15

Auto Fan Speed

The microprocessor automatically controls fan speed to

adjust the room temperature to the set temperature.

16

Streamer Discharge Air Purifying

The streamer discharge decomposes bacteria and mould

adsorbed by the indoor unit’s photocatalytic filter. After the particles are trapped, they are irradiated by the streamer device.

17

Mould-Proof Operation

The streamer discharge dries the inside of the indoor unit,

heat exchanger and airflow routes. It effectively prevents the

growth of both mould and odour-causing bacteria.

18

Cleaning Filter Operation

After operation stops, this function automatically brushes dust off the prefilter and collects it in a box. This helps to maintain filter performance and energy efficiency.

19

Titanium Apatite Photocatalytic

Air-Purifying Filter

This filter contains the advanced photocatalytic material

titanium apatite. While the filter’s micron-level fibres trap

dust, this photocatalyst adsorbs and decomposes bacteria. The filter can be used for up to 3 years with proper maintenance.

20

Child-Proof Lock

This function allows users to lock operation using the

wireless remote controller. It is useful for preventing setting

changes if children play with the controller.

21

Auto-Restart after Power Failure

The air conditioner memorises the settings for mode, airflow, temperature, etc., and automatically returns to them when power is restored after a power failure.

22

Self-Diagnosis with Digital Display

Malfunction codes are shown on the digital display panel of the wireless remote controller for fast and easy maintenance.

23

Anticorrosion Treatment of Outdoor

Heat Exchanger Fins

The outdoor unit’s heat exchanger fins are processed using a special anticorrosion treatment. The surface is covered with a thin acrylic resin layer to enhance the fins’ resistance to acid rain and salt corrosion.

24

Daily On/Off Timer

This timer allows users to set the operation start and stop times  so the air conditioner turns on and off at the same time every day.

25

24-Hour On/Off Timer

This timer can start or stop the air conditioner within a 24-hour period. It can be preset in 10-minute steps by pressing the On/Off timer button on the wireless remote controller. The On timer and Off timer can be used in combination.

26

Countdown Off Timer

The operation stop time can be preset for a period of 0.5 to 9.5 hours in 30 minute increments.

27

Quick Heating Timer

Heating operation can be preset to turn on one minute after

the set wakeup time. Warm airflow starts just one minute later.

 

Recommended: many kinds of wall mounted Daikin have the same cooling capacity

Wall mounted type of Daikin non-iniverter - Gas R32 - Model FTV50AXV1V/RV50AXV1V

Wall mounted type of Daikin non-iniverter - Gas R410A - Model FTNE50MV1V9/RNE50MV1V9

Wall mounted type of Daikin Inverter - Gas R410A - Model FTKS50GVMV / RKS50GVMV

Wall mounted type of Daikin nomal Inverter - Gas R32 - Model FTKC50VMV/RKC50NVMV

Wall mounted type of Daikin High Efficiency Inverter - Gas R32 - Model FTKV50NVMV/RKV50NVMV

Wall mounted type of Daikin High Efficiency Inverter - Urusara- Gas R32 - Model FTXZ50NVMV / RXZ50NVMV

Wall mounted type of Daikin High Efficiency Inverter - European Designed- Gas R32 - Model FTKJ50NVMVW(S)/RKJ50NVMV 

SIMILAR PRODUCTS
Chat facebook
Zalo
Viber